1.Product Introduction


The S2210 driver module is designed based on Trinamic's new generation chip TMC2210. Thanks to the brand-new architecture and process, its peak current can reach 3.0A, its continuous current can reach 2.1A, and it can withstand an input voltage up to 36V. TMC2100. All its functions only need to configure the IO hardware, no software programming is required.



2.Features


  • Hardware compatible with StepStick and Pololu A4988 Stepper Driver
  • Components on bottom PCB side for better heat emission
  • Automatic standby current reduction
  • StealthChop2™ silent PWM mode- for quiet operation and smooth motion
  • SpreadCycle - highly dynamic motor control chopper
  • Drive capability up to 2.1A (RMS) & 3.0A(PEAK) coil current
  • Step/Dir interface with microstep interpolation (up to 256 microsteps)
  • Input microsteps 1-64 optional
  • Configuration via CFG pins
  • Supply voltage 4.5-36V


3. Specifications Comparison


Model

TMC2100

TMC2209

TMC2210

Interface

Step/Dir

Step/Dir

Step/Dir

Configuration

CFG Pins

UART

CFG Pins

Native Microsteps

up to 1 ⁄ 16

up to 1 ⁄ 32

up to 1 ⁄ 64

microPlyer Microsteps

1 ⁄ 256

1 ⁄ 256

1 ⁄ 256

Logic Supply Voltage (VIO)

3.0 - 5.25V

3 - 5.25V

2.2 - 5V

Motor Supply Voltage (VM)

4.75 - 46V

4.75 - 28V

4.5 - 36V

Motor Phase Current max

1.2A RMS, 1.7A Peak

2A RMS, 2.8A Peak

2.1A RMS, 3.0A Peak

Internal V- Regulator

enabled

enabled

enabled

RDSon (typ. at 25°C)

LS 400mΩ & HS 500mΩ

170mΩ

230mΩ

Rsence

0.11Ω

0.11Ω

chip built-in

stealthChop (quiet)

yes

yes

yes

spreadCycle

yes

yes

yes

coolStep

no

yes

no

stallGuard

no

yes

no

dcStep

no

yes

no


4. Pin Functions



TMC2210-pin-definition


Pin

Function

 

Power Supply

GND

Ground

VM

Motor Supply Voltage

VIO

Logic Supply Voltage

 

Motor Outputs

B1

Motor Coil 1

B2

Motor Coil 1

A2

Motor Coil 2

A1

Motor Coil 2

 

Control Inputs

STEP

Step-Signal Input

DIR

Direction-Signal Input

 

CFG Pins

EN

Enable Motor Outputs: GND=on, VIO=off, OPEN=Auto-Power-Down

CFG0

Onboard pulled down,CONFIGURATION OF MICROSTEP RESOLUTION FOR STEP INPUT

CFG1

Onboard pulled down, CONFIGURATION OF MICROSTEP RESOLUTION FOR STEP INPUT

CFG2

Chip internal pull-up,CONFIGURATION OF RUN CURRENT IRUN (ALONG WITH IREF RESISTOR), DO NOT CHANGE DURING OPERATION

CFG5

Chip internal pull-up,SELECTION OF CHOPPER MODE

Index

Open drain index pulse output indicating, microstep 0 position of coil B.

Error

Open-drain error output. Use external pullup resistor.In system reset state, this pin is actively pulled low to indicate reset condition to external controller.

NC

No pins connected

 

Onboard Jumper

CFG3

Onboard pulled down,CONFIGURATION OF RUN CURRENT IRUN (ALONG WITH IREF RESISTOR), DO NOT CHANGE DURING OPERATION

CFG4

Onboard pulled down,DIGITAL CURRENT SCALE (MAY BE CHANGED DURING OPERATION)

CFG6

Onboard pulled up,CONFIGURATION OF HOLD CURRENT REDUCTION

CFG7

Onboard pulled down,CONFIGURATION OF HOLD CURRENT REDUCTION


5. Interface Resources



Wiring Diagram



TMC2210-wiring-diagram



5.1 Motor Current Setting


The current setting method of TMC2210 is slightly different, which is determined by CFG2 and CFG3 and the resistance value connected to IREF. Before we start, we need to clarify several relationships:


  • IRUN: The current when the motor rotates, set by CFG2 and CFG3 and the resistance value connected to IREF.
  • IHOLD: The current at which the motor is held still, set by CFG6 and CFG7.
  • IPEAK: Also known as Imax or Full Scale Current, the driver chip provides peak current (the peak value of the sine wave)
  • IRMS: The effective value of the current provided by the driver chip (the effective value of the sine wave, usually is about the peak value/1.41)


5.1.1. Setting the Full Scale Current Range

The full scale current IFS is a peak current setting. It is selected with an external reference resistor and the two configuration pins CFG2 and CFG3


Three different full-scale current ranges can be configured through the pins with the same reference resistor to adapt to different motor sizes and applications. This is needed to benefit from the best possible current control resolution.


Connect a reference resistor RREF from IREF to GND. Together with pins CFG3 and CFG2, the full scale current range IFS is set based on the external resistor .


The equation below shows the full-scale current IFS as a function of the RREF shunt resistor connected to pin IREF and the configuration pin setting. The proportionality constant KIFS is defined by the CFG2 and CFG3 setting. The external resistor RREF can range between 12kΩ and 60kΩ.


$$
I_{FS}=K_{IFS}(KV)/R_{REF}(kΩ)
$$


Table 9. IFS Full Scale Current Range Settings (Example for RREF = 12KΩ)


PIN CONFIG IN STANDALONE MODE

PIN CONFIG IN STANDALONE MODE

KIFS (A x kΩ)

MAX FS SETTING

TYPICAL RDS(ON) (HS + LS)

NOTES

1

1

36

3A

0.23Ω

Optimized efficiency for motors and applications rated up to 2.1A rms

1

0

36

3A

0.23Ω

Optimized efficiency for motors and applications rated up to 2.1A rms

0

1

24

2A

0.27Ω

Optimized efficiency for motors and applications rated up to 1.4A rms

0

0

11.75

1A

0.40Ω

Optimized efficiency for motors and applications rated up to 0.7A rms



5.1.2. Setting the Rref


IFS Full Scale RMS Current in Ampere (A RMS) based on CFG2/CFG3 Pin Settings and different RREF

RREF(kΩ)

KIFS = 24

12

1.41

15

1.13

18

0.94

22

0.77

27

0.63

33

0.51

39

0.44

47

0.36

56

0.30


According to the circuit of the module, we perform this demonstration calculation:
Rref: The resistor connected to the IREF pin, which consists of a 12K resistor and a maximum 50K adjustable resistor. The factory value of the adjustable resistor is generally located in the center, which is 25K, and all default Rref=37K.
CFG3 is pulled down by default, which is equivalent to the GND level, and CFG2 is high when no external level is connected, so the default KIFS=24KV.


$$
I_{FS}=K_{IFS}(KV)/R_{REF}(kΩ)=24(KV)/37(KΩ)=0.65A
$$


5.1.3 Hold Current (IHOLD) Reduction Configuration



CFG7(Onboard pulled down)/CFG6(Onboard pulled up
: CONFIGURATION OF HOLD CURRENT REDUCTION


CFG7

CFG6

HOLD CURRENT REDUCTION

GND

GND

No hold current reduction. IHOLD = IRUN

GND

VCC_IO

Reduction to 50%. IHOLD = 1/2 IRUN

VCC_IO

GND

Reduction to 25%. IHOLD = 1/4 IRUN

VCC_IO

VCC_IO

Reduction to 12.5%. IHOLD = 1/8 IRUN


5.1.4 Digital Current Scale Configuration



CFG4(Onboard pulled down
: DIGITAL CURRENT SCALE (MAY BE CHANGED DURING OPERATION)


CFG4

CURRENT SCALE

GND

I = 75% of full scale current IRUN

VCC_IO

I = 100% of full scale current IRUN


5.3 Microsteps Setting


Microsteps Resolution Configuration for the Step Input,
CFG1(Onboard pulled down )CFG0(Onboard pulled down
,So the default is 8 microsteps.


CFG1

CFG0

microsteps

Interpolation

Mode

GND

GND

8

256

StealthChop2

GND

VIO

16

256

StealthChop2

VIO

GND

32

256

StealthChop2

VIO

VIO

64

256

StealthChop2


TMC2210-jumper-diagram


6. Other Configs


6.1 Chopper Mode Selection


CFG5 (Chip internal pull-up)
: SELECTION OF CHOPPER MODE


CFG5

CHOPPER MODE

GND

SpreadCycle operation

VCC_IO

StealthChop2 operation



7. How to config the code in klipper/marlin


S2210 only needs to configure the corresponding STEP, DIR, EN pins on the software, no additional configuration is required.
It is worth noting that the subdivision parameters on the software need to be consistent with the jumpers on the hardware.


For example, the X-axis configuration in klipper is as follows:


[stepper_x]
##	Connected to X-MOT (B Motor)
step_pin: PE11
dir_pin: PE10
enable_pin: !PE9
rotation_distance: 40
microsteps: 8
full_steps_per_rotation:200  #set to 400 for 0.9 degree stepper
endstop_pin: ^PB14
position_min: 0

##--------------------------------------------------------------------
position_endstop: 300
position_max: 300
##--------------------------------------------------------------------
homing_speed: 25   #Max 100
homing_retract_dist: 5
homing_positive_dir: true


Any configuration such as [tmc2209 stepper_x] is no longer needed.



NOTE:



Pay attention to the direction.


  1. The heat sink is directly attached to the PCB.
  2. The motor direction is the opposite of 4988 and 8825. If you want to replace the 4988 directly, please adjust the firmware or adjust the motor connection.



Documents


SCH: https://github.com/FYSETC/S2210/blob/main/TMC2210%20V10.pdf


Datasheet: https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2210_datasheet_rev1.pdf



Shop



Tech Support



Please submit any technical issue into our forum

Updated on: 01/07/2026

Was this article helpful?

Share your feedback

Cancel

Thank you!